HEMM Vibration and Noise Dose Simulator
A simulated operator seat and cab on a mining machine, processed the way the DFMS edge unit processes it: ISO 2631-1 vibration weighting with daily A(8) and VDV, A-weighted cab noise with LEX,8h and C-weighted peak, data-quality checks, events joined to the DFMS timeline, and a long-term dose ledger. Everything runs inside the mine's network.
Whole record · 1-s rms, Z
Whole record · 1-s LAeq at the ear, dB(A)
Data-quality checks on the edge
Run on every record before any number goes to a report or a dose ledger. A record that fails is held for review, not averaged in.
One timeline: WBV + noise + DFMS
Vibration, noise and DFMS events share machine ID, operator ID and timestamp, so they land on the same record. DFMS entries here are simulated.
How WBV joins the existing DFMS, on premise
The vibration engine runs where DFMS already runs. Raw signal stays on the machine; summaries and events travel over the site network to the mine's own server.
- Tri-axial seat-pad accelerometer (ISO 10326-1 position)
- Optional floor or frame sensor for continuous screening
- Class 2 microphone near the operator's ear (IEC 61672-1)
- DFMS cabin cameras
- CAN / J1939, GNSS where available
- Wk / Wd weighting, rms, A(8), VDV, MTVV, crest factor
- A-weighted LAeq, LEX,8h and C-weighted peak
- Clipping, seat-pad, microphone and idle checks
- Raw-signal ring buffer for ISO 2631-5 and audits
- Operator ID and seat occupancy taken from DFMS
- Store and forward when the network drops
→
- Message broker and time-series store
- Per-operator daily dose ledger
- Dashboard by machine, road segment, shift
- Compliance report export (PDF / CSV)
- Role-based access; no internet needed
OPC UA →
- Installed DFMS or FMS (any vendor with an export or API)
- Shift roster / HR
- Periodic medical exam records, restricted access
- Mine's own safety reporting
A cloud copy (the mine's own GCP or AWS account) is optional and holds only what the mine releases. Medical records never leave the site server.
| Site situation | What we add | Where operator identity comes from | Effort |
|---|---|---|---|
| GoatAI DFMS already on the machine | Accelerometer plus a software module on the same edge unit | DFMS face match and seat occupancy | Sensor fit and configuration |
| Another vendor's DFMS installed | Small WBV logger per machine, publishing to the site server; joined to DFMS records by machine ID and time | DFMS event export or API, or FMS login | Interface review with the DFMS vendor |
| No DFMS yet | Standalone WBV logger and the same site server | Shift roster import | Lowest; DFMS added later on the same unit |
Message published every simulated minute
Cumulative dose at 5, 10 and 15 years
The current shift's A(8) becomes a daily dose. Adding those up over working years gives each operator a ledger, and each control option a measurable reduction. The chart shows dose, not a diagnosis.
Dose unit: one action-value year is 250 days at A(8) = 0.5 m/s² (energy-equivalent, A(8)² × days). Reductions for seat, road and rotation come from this simulator's illustrative model and must be measured on site before they are quoted. Turning dose into a probability of low-back disorder needs a dose-response relation calibrated on the mine's own medical records and a cohort follow-up. ISO 2631-5 spinal dose needs the raw signal, which the edge unit keeps.
What each control does to the noise dose
Noise has Indian reference levels: DGMS guidance sets 85 dB(A) as the warning level and 90 dB(A) as the danger level over 8 hours. A plug only counts while it is in the ear: taking it out for a fifth of the shift cuts its benefit from about 26 dB to about 7 dB.
Daily dose uses the equal-energy rule (3 dB doubles the dose) with 90 dB(A) for 8 h as 100%; the edge can also report the 5 dB rule used in some Indian factory rules. Hearing-protector benefit uses SNR less 4 dB for real-world fit. Noise-induced hearing loss builds over years: pairing LEX,8h with audiometry in the periodic medical exam shows who is drifting before it becomes a notified case.